Home » Shop » hot sale » UEI DL479AC600A TRMS HVAC/R CLAMP METER, SINGLE DISPLAY

UEI DL479AC600A TRMS HVAC/R CLAMP METER, SINGLE DISPLAY

Original price was: $94.32.Current price is: $71.27.

Sale!

12 in stock

SKU: DL479 Category:

AC 600A True RMS HVAC/R Clamp Meter

Includes:

  • Test leads, w/alligator clips
  • Thermocouple temperature probe
  • Zippered pouch
  • Batteries 2 (AAA)
  • Manual

Functions:

  • True RMS
  • 600A AC
  • 750V AC/600V DC
  • Resistance 60M?
  • Capacitance 2000µF
  • Temperature 14° to 752°F (-10° to 400°C)
  • DC microamps 2000µA
  • Frequency/Duty cycle
  • Diode test
  • Non-contact voltage detection
  • Audible continuity
  • 2-Year limited warranty

Applications:

  • Motor or line current
  • Control voltage or system board voltage checks
  • Circuit continuity or specified resistance
  • Flame safe guard
  • Quick check of live wires
  • Diode malfunctions/unbroken paths

Specification

AC Amps – Jaw Input
Range 60A / 600A
Resolution 0.01A / 0.1A
Accuracy ±(2.0% +8 dgts)
Overload Protection 600V RMS
True RMS Frequency Range Sine 50Hz to 400Hz
Frequency width: 60Hz to 400Hz 5% to 95%
Frequency width: 400Hz to 4kHz 15% to 85%
AC Volts (45Hz to 400Hz)
Range 600mV / 6V / 60V / 600V / 750V
Resolution 0.1mV / 1mV / 10mV / 100mV / 1.0V
Accuracy ±(1.0% +3 dgts)
Overload Protection 1000V RMS
True RMS Frequency range Sine 50Hz to 400Hz, Sine 50Hz to 400Hz
Bandwidth Sine = 0.5% error at 1.5kHz (max)
Bandwidth Square= 0.5% error at 0.1kHz (max)
Bandwidth Triangle = 0.5% error at 1.2kHz (max)
DC Volts
Range 600mV / 6V / 60V / 600V
Resolution 0.1mV / 1mV / 10mV / 100mV
Accuracy ±(0.5% +4 dgts)
Overload Protection 1000V RMS
DC Low Amps
Range 600µA / 2000µA
Resolution 0.1µA / 1.0µA
Accuracy ±(1.2% +3 dgts)
Overload Protection 2000µA/600V RMS
Resistance
Range Resolution Accuracy
600? 0.1? ±(0.8% +3 dgts)
6k? 1?
60k? 10?
600k? 100?
6M? 0.001M?
60M? 0.01M? ±(1.2% +3 dgts)
Overload Protection 600V RMS
Frequency
Range Resolution Accuracy
99.99Hz 0.01Hz ±(0.1% per+3 dgts)
999.9Hz 0.1Hz
9.999kHz 0.001kHz
Overload Protection 600V RMS
Duty Cycle
Range 0.5% to 95% 60Hz to 400Hz / 15% to 85% 400Hz to 2kHz
Resolution 0.1%
Accuracy ±(0.2% per kHz +2.0% +2 dgts)
Overload Protection 600V RMS
Sensitivity> 6Vpp RMS
Diode Test
Range 4.0V
Open Circuit V <3.0V DC
Test Current 1.30mA
Overload Protection 600V RMS
Capacitance
Range Resolution
60nF 0.01nF
600nF 0.1nF
6.000µF 0.001µF
60.00µF 0.01µF
600.0µF 0.1µF
2000µF 1µF
Accuracy ±(3.0% +5 dgts)
Overload Protection 600V RMS
Continuity
Open Circuit V <1.0V
Response Time <50ms
Overload Protection 1000V
Temperature
Range 14° to 752°F / -10° to 400°C
Resolution 0.1°F / 0.1°C
Accuracy ±(1.5% +3.6°F) / ±(1.5% +2.0°C)
Overload Protection 600V RMS
Stated accuracy does not account for themocople accuaracy Sensitivity>2Vpp RMS
Non-Contact Voltage
On Voltage
Approx. 25V AC